Call for tenders – Gomal Zam project in Pakistan

25 May 2001


A feasibility study carried out for WAPDA concludes that the project should comprise a curved, 133m high, roller compacted concrete gravity dam with a radius of 150m. A spillway is to be built on the middle part of the dam, initially with four bays, four long chutes and flip buckets. Maximum capacity of the spillway will be 433m3/sec. A 2.2x3m bottom outlet opening, with a discharge capacity of 250m3/sec, will be placed at 29.9m above the river bed. A 17.4MW power house will be situated in a cavern 18m high, 9m wide and 37m long.

Interested firms should contact the chief engineer at WAPDA on +92 42 920 2797, fax: +92 42 920 2798. The closing date is 22 July, 2001.




Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.