Three-dimensional stress intensity factor evaluation routine for the investigation of cracking in dams - special features

17 September 2004


Transient heat transfer or dynamic-induced stress developments in precracked dam structures may be seen as characteristic examples for fracture mechanics investigations under special conditions. Both effects require the use of special contact elements in connection with opening and closing of the crack faces. As a further consequence the crack tip area in the present case had to be represented by 27-node (distorted) brick elements to obtain element compatibility.

A routine quite similar to the 20-node element stress intensity factor (SIF) evaluation procedure representing the SIF distribution along the crack front is presented. The method is demonstrated via a fracture study of a thermally affected crack in a buttress dam.



Want to read the full paper?

To purchase a copy of this Dam Engineering paper, please email the Editor, Carrieann Davies, on: cdavies@wilmington.co.uk or fax: +44 (0) 20 8269 7804.
Please include your name, postal address, credit card number and issue number.
The cost is £20 sterling for each paper, postage & handling free.
Your order will be confirmed by email. We aim to dispatch your order within 48 hours of receipt.





Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.