Cardiff-Weston vs Shoots

1 January 2000


Cardiff-Weston vs Shoots – a comparison of the barrage schemes
Cardiff-Weston barrage The Shoots barrage
Length of barrage 15.9m 6.5m (approx)
Turbine No x runner dia. 216 x 9m 30 x 7.6m
Type of turbine Bulb, fixed distributor, Straflo or rim generator,
No of turbines/Caisson 4 2
Generator capacity 40MW 35MW
Total installed capacity 8,640MW 1,050MW
Annual energy output
with reverse pumping 17TWh (Approx) 2.75TWh
Annual energy, ebb
generation only 16.5TWh(approx) 2.75TWh
Contribution to UK
electricity supply
(2006 data) 4.40% 0.70%
Capital cost (2006) £15B £1.4B-£1.8B
Annual O&m costs £115M £22M-£27M
Unit cost of electricity 3.6-22.3 p/kWh 3-15.4 p/kWh
Annual saving in CO2
based on 0.43kg/kWh 7.3M tonnes 1.2M tonnes
Lifetime carbon saving 877M tonnes 142M tonnes
Environmental aspects Both schemes need to fish passes and injury
look at sedimentation; injury passing through



Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.