Table 1

1 January 2000


Table 1. Compressive Strength and Variability for RCC Spillways - QA Control Cylinders1/ CW Continuous Weigh Plant; CV Continuous Volumetric Plant; BW Individual Batch Weigh Plant; P Pugmill Mixer; C Compulsory Mixer; D Drum Mixer2/ * Standard deviation and coefficient of variation for the indicated design strength and test age.3/ Cores tested two to three years after construction.
Structure Batchplant Type 1 C+P Content W/(C+P) Ratio Compressive strength (lb/in2) Standard deviation Coefficient of variation
Ib/yd3 28 day 90 day 1 year ib/in2 %
Cold Springs CW-P 292+0 0.52 5670* 7280 3/ 540 2/ 9.5 2
Ochoco CV-P 434+0 0.50 4930* 6230 1335* 27*
0.55 3936 3 733 19
0.45 6265 543 9
Pueblo BW-C 120+180 0.47 2230 4830* 430 9
Many farms BW-C 141+280 0.37 5480 6635* 7020 566* 8.5



Privacy Policy
We have updated our privacy policy. In the latest update it explains what cookies are and how we use them on our site. To learn more about cookies and their benefits, please view our privacy policy. Please be aware that parts of this site will not function correctly if you disable cookies. By continuing to use this site, you consent to our use of cookies in accordance with our privacy policy unless you have disabled them.